Table R301.2(1) of the IRC shall have the following design criteria:

Table R301.2(1). Climatic and Geographic Design Criteria

GROUND SNOW LOAD

25

WIND DESIGN

Speedd (mph)

110

Topographic effectsk

NO

Special wind regionl

NO

Wind-borne debris zonem

NO

SEISMIC DESIGN CATEGORYf

D2

SUBJECT TO DAMAGE FROM

Weatheringa

MODERATE

Frost line depthb

18"

Termitec

SLIGHT

WINTER DESIGN TEMPe

22

ICE BARRIER UNDERLAYMENT REQUIREDh

NO

FLOOD HAZARDg

1985; 2005; 53061C1305E 53061C1310E 53061C1309E 53061C1320E 53061C1315E All adopted 11/08/1999

AIR FREEZING INDEXi

1500

MEAN ANNUAL TEMPj

52.8

(Ord. 3396 § 5, 2021; Ord. 3196 § 5, 2016; Ord. 3006 § 3 (Exh. C), 2013; Ord. 2840 § 5, 2010; Ord. 2683 § 4, 2007)