A. Storage Tanks. All storage tanks proposed to be located in a critical aquifer recharge area must comply with local building code requirements and must conform to the following requirements:

1. Underground Tanks. All new underground storage facilities proposed for use in the storage of hazardous substances or hazardous wastes shall be designed and constructed so as to prevent releases due to corrosion or structural failure for the operational life of the tank; be protected against corrosion, constructed of noncorrosive material, steel clad with a noncorrosive material, or designed to include a secondary containment system to prevent the release or threatened release of any stored substances; and use material in the construction or lining of the tank that is compatible with the substance to be stored.

2. Aboveground Tanks. All new aboveground storage facilities proposed for use in the storage of hazardous substances or hazardous wastes shall be designed and constructed so as to not allow the release of a hazardous substance to the ground; have a primary containment area enclosing or underlying the tank or part thereof; and have a secondary containment system either built into the tank structure or a dike system built outside the tank for all tanks.

B. Vehicle Repair and Servicing.

1. Vehicle repair and servicing must be conducted over impermeable pads and within a covered structure capable of withstanding normally expected weather conditions. Chemicals used in the process of vehicle repair and servicing must be stored in a manner that protects them from weather and provides containment should leaks occur.

2. No dry wells shall be allowed in critical aquifer recharge areas on sites used for vehicle repair and servicing. Dry wells existing on the site prior to facility establishment must be abandoned using techniques approved by the state Department of Ecology prior to commencement of the proposed activity.

C. Residential Use of Pesticides and Nutrients. Application of household pesticides, herbicides, and fertilizers shall not exceed times and rates specified on the packaging.

D. State and Federal Regulations. All of the above listed uses, and other uses where state and federal regulations apply, shall be conditioned as necessary to protect critical aquifer recharge areas in accordance with the applicable state and federal regulation. In addition, any water reuse projects for reclaimed water must be in accordance with the adopted water or sewer comprehensive plans that have been approved by the State Departments of Ecology and Health, and must meet the ground water recharge criteria given in RCW 90.46.010(10) and 90.46.080(1). The State Department of Ecology may establish additional discharge limits in accordance with RCW 90.46.080(2). (Ord. 3193 § 2, 2016)