21.43.200 Development standards.
Standard |
RML |
RMM |
RMH |
---|---|---|---|
Minimum Lot Area |
7,200 sf |
none |
none |
3,600 sf |
2,400 sf |
1,000 sf |
|
Minimum Lot Width |
70 ft. |
70 ft. |
100 ft. plus 1 ft. for every 10 ft. of lot depth after the first 100 ft. |
Minimum Frontage at Street |
70 ft. |
70 ft. |
70 ft. |
Minimum Front Yard Setback |
|||
15 ft. |
15 ft. |
15 ft. |
|
15 ft. |
15 ft. |
15 ft. |
|
Abutting a Principal Arterial Street |
15 ft. |
15 ft. |
15 ft. |
Minimum Side Yard Setbacks – Corner Lot |
|||
Street Side |
15 ft. |
15 ft. |
15 ft. |
Interior Side |
5 ft. |
15 ft. |
15 ft. |
Both Sides Combined |
20 ft. |
30 ft. |
30 ft. |
Abutting a Principal Arterial Street |
15 ft. |
15 ft. |
15 ft. |
Minimum Side Yard Setbacks – Interior Lot |
|||
One Side |
5 ft. |
15 ft. |
15 ft. |
Both Sides Combined |
15 ft. |
30 ft. |
30 ft. |
Minimum Rear Yard Setback |
25 ft. |
25 ft. |
25 ft. |
Maximum Lot Coverage by Buildings |
35 percent |
35 percent |
45 percent |
Maximum Building Height |
35 ft., or 2 stories from average finished grade |
35 ft. |
none |